This application form is for an electrician's licence to carry out electrical fitting work on completion of the Gap Training Program (Gap Training), which resulted in the issue of a Certificate III in Electrical fitting.
Application form This application form is for an electrician's licence to carry out electrical fitting work only for overseas applicants who have been issued an Australian recognised trade...
Application form This application form is for applicants who have completed the Electrical Trades Licensing (ETL) Gap Training Course. Application for Electricians Licence on completion of electrical...
This application form is for an electrician's licence on completion of the Australian Minimum Context Training Program (gap training), which resulted in the issue of a Certificate III in Electrotechnology Electrician.
Application form This application form for an electrician's licence is for overseas applicants issued an offshore technical skills record (OTSR) for the nominated occupation of electrician (general...
Application forms These application forms are for an electrician's training licence for an indentured apprentice. Electricians training licence for an indentured apprentice – R116 Form: Electricians...
Application forms These applications are to be used for applicants undertaking training as a pre-apprentice. Electrician's training licence (for pre-apprenticeship) – R117 Form: Electrician's...
Application form This application form is to be used by a person holding an electrician's licence endorsed 'electrical fitting work only' wishing to upgrade to a full electrician's licence. Upgrade...
30 January 2024 Beware - Scammers Targeting Perth Property Sales Consumer Protection is reminding the real estate and settlement industry that identity validation checks are a mandatory part of the...
Real estate and business agents wishing to complete activities towards the Business Broking professional development subject (Schedule 1A of the Regulations) can select from the approved activities...
The Mines Statutory Positions Register is used to validate an individual’s statutory position examination or certificate under the Work Health and Safety (Mines) Regulations 2022. Statutory positions...
Excavation of a pipeline within a compressor station for the purpose of inspecting the coating integrity resulted in an excavator damaging the pipeline coating. The incident was exacerbated by a lack...
A side-boom was working in tandem with a second side-boom to move a pipeline segment into a trench. The working side of the trench had been elevated by placing the spoil on that side. The segment...
During works at a compressor station, an excavator struck and fractured a 2 inch diameter utility line. Fortunately, no ignition occurred nor were there any injuries. However, the compressor station...
A gas leak occurred at a compressor station when small bore pipework fractured. The incident resulted in a small natural gas release that was successfully resolved without harm, although the licensee...
In late 2010 when a well site was being demobilised, a handrail fell from the sub-base walkway of a draw works skid being moved and struck a worker walking below at ground level. The initial contact...
During a tong jaw change-out operation on a rig floor, a crew member tapped the tong jaw into position using a rubber mallet to insert the pin while two other crew members held the tong to stabilise...
A hydraulic cylinder used to lower and raise a rig’s derrick was found to be faulty and was replaced with a substituted part, rather than that supplied by the original equipment manufacturer (OEM)...
During a mechanical inspection of the crown block on top of a drilling derrick, one of the turnbuckles on the side brake was found to be fractured. A decision was made to repair weld the turnbuckle...
A new member of a drilling crew was asked to clear excess drill cuttings around a “possum belly”. Also known as a distribution box or flowline trap, this part of a drilling rig slows the velocity of...
At the beginning of a work-over operation on an oil well, a mobile lighting tower was erected to provide light during night activities. A few days later, the tower fell onto the lighting plant...
After a cleaning pig run of an oil pipeline, the pig (pipeline inspection gauge) was cleaned, dismantled, checked and reassembled. A cotter pin was required to complete the job. A worker involved in...
An electrical supervisor conducting a walkabout after a pre-start noticed smoke and heard a strange noise coming from a generator. Assuming it could be running out of fuel, he lifted the access cover...
The travelling block of a work-over rig struck the crown of the derrick. After the block hit the crown, the derrick tilted slightly away from the rig floor towards draw works, resulting in failure of...